The primary goal of fire-rated and smoke-rated openings is to protect lives, and their design, selection, application, and maintenance come with great responsibility. Therefore, fire-rated and smoke-rated openings, as well as their manufacturing, must meet a number of standards and legal requirements, and proof of compliance must be provided. Alongside these requirements, aesthetic and practical considerations can be taken into account.

Coolfire Ltd.’s expertise, product suitability, and reliability are supported by:

  • Being pioneers in introducing aluminum-framed glazed fire-rated and smoke-rated openings in Hungary.
  • Over 15 years of market experience.
  • The successful application and maintenance of fire-rated openings in numerous buildings, ensuring durability and trouble-free usage.

The Coolfire – FR, BR frameless fire-rated glass wall system is a unique development that eliminates steel and aluminum frames and vertical dividing bars, offering an exclusive, modern, and striking appearance. The absence of frames increases the usable glass surfaces, allowing natural light to be more prominent. Exceptionally large glass panels can be used, making it suitable for replacing non-load-bearing infill walls.

It can also be used as a standalone arched skylight or as a side light for Coolfire – Sapa 74 fire-rated doors.

COOLFIRE - FR, BR Fire-Rated Frameless Glass Wall Systems

COOLFIRE – FR, BR Fire-Rated Frameless Glass Wall Systems

Indoor application integrated with door - NMÉ marking

When used as a side glazing for a fire-resistant door, the results jointly tested with the door must be taken into account, as specified in the National Technical Approval (NMÉ).

The basis of the National Technical Assessment (NMÉ) includes the fire and smoke resistance test results according to EN 1634-1:2014, EN 1634-2:2014, EN 1634-3:2006, the performance characteristics of interior doors according to the non-harmonized EN 14351-2, classification certificates according to EN 13501-2, the guidelines for automatic doors according to EN 16005 together with the 2006/42/EK Machinery Directive, and manufacturing quality control (ÜGYE).

The Performance Declaration issued based on these standards certifies the properties and performance of the installed product.

Note that CE marking is NOT applicable to internal doors!

Installed door and window units must be labeled with a “Product Identification Plate,” including product identification, the name of the certifying body, NMÉ, ÜGYE, and TÁT number.

Types:

Coolfire – BR frameless fire-rated glass wall system integrated with Coolfire – Sapa74 EI door

  • Coolfire – Sapa 74 fire-rated glass door can be integrated.
    Fire resistance rating: EI30, EI60, EI90.
  • Fire resistance rating: EI30, EI60, EI90

Performance EI30, S200 NMÉ: A139/2018
Performance EI60, S200 NMÉ: A138/2018
Performance EI90, S200 NMÉ: A11/2018

The use of it in an insulated form is not possible.

Indoor use as a standalone glass wall - CE marking

This European Technical Assessment (ETA) was issued in accordance with Regulation 305/2011/EU based on the ETAG 003, December 1998 edition, with the April 2012 amendment, and is used as a European Assessment Document (EAD).

For non-load-bearing fire-resistant glass walls, the basis for the Performance Declaration confirming their performance consistency is:

  • ETA: 16/0590 (2018.08.31)
  • Classification according to MSZ EN 13501-2:2016-07 for fire protection
  • Fire protection classification determination according to MSZ EN 13501-1+A1:2010
  • Glass construction characteristics according to MSZ EN 410
  • Sound insulation values of glass constructions according to MSZ EN 12758
  • Resistance to impact from a swinging body according to MSZ EN 12600

Types:

Coolfire – FR frameless fire-rated glass wall system

  • Independent (non-assembled) glass wall system, available in standard, curved, or custom shapes
  • Fire resistance ratings: EI30, EI60, EI90, EI120, EI180

Coolfire – BR frameless fire-rated glass wall system

  • Coolfire – Sapa 74 fire-rated glass door integrable
  • Fire resistance rating: EI30, EI60, EI90, EI120

Performance EI30  CE:
Performance EI60  CE:
Performance EI90  CE:
Performance EI120  CE:

The use of it in an insulated form is not possible.

Special custom solutions, properties:

The Coolfire FR, BR fire-resistant frameless glass wall system is a new, innovative product line that expands the application possibilities for safely sealing fire compartments based on the following key aspects and needs:

  • Modern, decorative appearance
  • Provision of natural light
  • Compatibility with integrated glass doors
  • Can replace drywall or brick wall sections between ceilings, used as large surface areas

Special properties:

  • Wide selection of fire resistance ratings: EI30, EI60, EI90, EI120, EI180
  • Self-supporting glass panels, frameless, either standalone (FR) or side-by-side (BR)
  • Suitable for curved top closures, such as large arches
  • Can be installed in straight lines, at angles, or in curves
  • Easy installation
  • Various edge covering options ensure optimal adaptation to the environment
  • Excellent sound insulation and light transmission capabilities
  • Large glass panels with minimal joints, breaking up the surface with minimal seams

Good value for money, comparable to framed systems in pricing.

For sealing interior fire compartment boundaries with fire-resistant closures, it can be used as a wall, fixed window, side light, or integrated with a glass door.

It can be applied as a glass wall in hallways, arches, and for sealing openings of various sizes:

In public buildings, shopping centers, hospitals, office buildings, and residential buildings, where aesthetic and modern appearance and natural light are important.

It is suitable for use in interior spaces.

Request a quote

Call us if you have any questions

Technical advice:
Quote: