The primary goal of fire-rated and smoke-rated openings is to protect lives, and their design, selection, application, and maintenance come with great responsibility. Therefore, fire-rated and smoke-rated openings, as well as their manufacturing, must meet a number of standards and legal requirements, and proof of compliance must be provided. Alongside these requirements, aesthetic and practical considerations can be taken into account.

Coolfire Ltd.’s expertise, product suitability, and reliability are supported by:

  • Being pioneers in introducing aluminum-framed glazed fire-rated and smoke-rated openings in Hungary.
  • Over 15 years of market experience.
  • The successful application and maintenance of fire-rated openings in numerous buildings, ensuring durability and trouble-free usage.

The Coolfire – Sapa74 fire-rated aluminum profile glass automatic door is a certified product family developed and manufactured by Coolfire. It has been tested together with actuators: Record and FAAC automation systems, which comply with the EN 16005 and EN 13489-1PI “c” EU standard requirements.

The validated and applicable size range provides numerous possibilities for various solutions on facades and in interior spaces.

COOLFIRE - Sapa 74 Fire-Rated Automatic Glass Door

COOLFIRE – Sapa 74 Fire-Rated Automatic Glass Door

Facade Application - NMÉ Marking

MSZ EN 16034 – Entrance Doors, Industrial, Commercial, Garage Doors, and Windows Product Standard, Performance Consistency (Fire Resistance and/or Smoke-tight Characteristics) according to the NMÉ – Certified Performance Declaration confirming the properties and performance of the installed fire-rated openings.

NMÉ Basis:

  • MSZ EN 14351-1 Harmonized standard for entrance doors, windows, and garage doors, as well as their fire and smoke-tight performance characteristics.
    (This will replace MSZ EN 16361:2013+A1:2016, Mechanical operation of pedestrian doors. Product standard, performance characteristics.)
  • MSZ EN 13501-2+2016:07 Classification according to fire protection.
  • MSZ EN 16005 Directive for the safe installation of electrically operated pedestrian and commercial doors, to be handled together with 2006/42/EK Machinery Directive.
  • ÜGYE – Production Control

Installed Doors and Windows must be provided with “Product Identification Plates” including product identification, the name of the certifying institution, NMÉ, ÜGYE, and TÁTs serial number.

Facade Properties to be Verified:

  • EN 12211:2001 Wind resistance: 600 Pa
  • EN 12208:2001 Water tightness: 1A Class
  • EN 12207:2001 Air tightness: 2 Class
  • EN 13049:2001 Safety – Mechanical strength: 4 Class

Other:

  • EN 1191 C5 Durability, 200,000 opening cycles

Indoor Application - NMÉ Marking

According to the 305/2011/EU European Parliament and Council Regulation, and the 275/2013 (VII. 16.) Government Decree, the performance consistency of fire- and smoke-resistant doors and windows for indoor use is certified by the National Technical Assessment (NMÉ).

The basis of the NMÉ: the fire and smoke resistance test results of EN 1634-1:2014, EN 1634-2:2014, EN 1634-3:2006, the performance characteristics of non-harmonized EN 14351-2 interior doors, classification records according to EN 13501-2, the EN 16005 guidelines for electrically operated doors, together with the 2006/42/EK Machinery Directive, and production control (ÜGYE).

The Performance Declaration issued based on this certifies the properties and performance of the installed product.

CE marking is NOT applicable to interior doors!

Installed doors and windows must be equipped with “Product Identification Plates,” including product identification, the name of the certifying institution, NMÉ, ÜGYE, and TÁTs serial number.

APPROVALS FOR INTERIOR AND FACADE USE:

Coolfire – Sapa 74 EI automatic glass door product family:
Performance EI30, S200  NMÉ: A139/2018
Performance EI60, S200  NMÉ: A138/2018
Performance EI90, S200  NMÉ: A11/2018

Special custom solutions, properties:

Coolfire – Sapa74 EI Fire-Rated Automatic Glass Doors – Coolfire Design – Development for High-Traffic Entrances with Fire-Rating Functions

  • EI30 and EI60 fire resistance and/or S200 smoke resistance performance
  • Can be used independently as a smoke-resistant door
  • Suitable for both interior and façade applications
  • Not suitable for escape routes
  • Designed for intensive and continuous use (C5 rating)
  • Tested electrical operators and controllers: Record, Faac
  • The electrical operators are equipped with modern protective functions as required by standards and regulations
  • Maintenance and service support ensure long-term continuous operation

The fire-tested Coolfire – Sapa74 Automatic Glass Door System and its electrical drives comply with the Machinery Directive 2006 / 42 / EG and the following European harmonized standards have been applied:

  • EN 16005:2012
  • EN ISO 12100:2010
  • EN 60335-2-103:2015
  • EN 13849-1:2015
  • EN 13849-2:2012

Not suitable for escape routes, but can be used for fire- and/or smoke-resistant closures at fire compartment boundaries.

Recommended for: hospitals, department stores, office buildings, factories, public buildings:

  • Openings in areas with high pedestrian traffic
  • Health-related needs, where “handle-free” passage is important
  • For use on paths for people with disabilities
  • For passage by wheelchair users, carts, or patients in beds

Hospitals, department stores, office buildings, factories

Can be used with access control systems and remote opening.

Request a quote

Call us if you have any questions

Technical advice:
Quote:

Fire-rated products