Frameless fire-resistant glass wall systems

COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120


COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120

 

Exclusively available from us. Safe, decorative product range at affordable price.

Our fire-rated glass wall range provides an outstanding interior design without the usual limitations. It is no longer a problem to apply large decorative glass surfaces with frameless joints at a fire section border.

It is also possible to connect the glass panels together in a curve or angle.


Application:

They can be used in public buildings, shopping malls, hospitals, office buildings, residential buildings, where the decorative and modern look, and natural light are important. They can also be used in indoor spaces.


Look:

The frameless glass wall elements can be connected to the Coolfire-Sapa 74 EI30, EI60, EI90 fire-rated glassdoor range.
The fire-rated glasses can be B1,B2 safety rated, insulated, provided with “smart” colour changing function, tinted.

It is also possible to connect the glass panels together horizontally or in a curve or angle.

COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120

Types:

Multiple module glass walls (BR): The glass panels can be connected with 2mm gaps, the gaps are filled with special black fire-rated silicone.

Individually installed glass panels (FR): The aim of this installation is to provide the largest possible glass surface without any interruption. For these types of glass installations, the wall structure completely surrounds the glass, creating complete harmony.


Suitable wall structures / building construction:

The structure can be installed in Brick/ concrete/ Aerated concrete/ Mounted plasterboard wall structure, or substituting them

The cover of the glass wall edges:

Can be nailed in a way that best fits the venue. The edges of the installed FR, BR fire-rated glass wall structures could be covered as required to best suit the venue. See some options:

Atrr08
Attr9
Attr10
Attr11

 

 

 
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
 

 

BR variant Fire resistance Max. Glass
size in mm
Thickness in mm Light transmission
in %
Rw (dB) Weight
kg/m2
U-value
(W/m2K)
DoP
BR-EI30
Straight connection or
double glazed unit (DGU)**
EI30 2200 x 4200 30** 84,9 43 65 4,6 No. 4335/P-CPR/2022
BR-EI30
Angled connection
EI30 2200 x 3500 30 84,9 43 65 4,6 No. 4335/P-CPR/2022
BR-EI60
Straight connection, angled connection
or double glazed unit (DGU)**
EI60 1500 x 3000 35** 84,5 44 69 4,2 No. 4168/P-CPR/2022
BR-EI90
Straight connection
EI90 2200 x 3850 45  84,0 47  82  3,2 No.4326/P-CPR/2022
BR-EI90
Straight connection with
double glazed unit (DGU)**
EI90 2420 x 4620 45**  84,0 47 82 3,8 No.4326/P-CPR/2022
BR-EI120
Straight connection
EI120 1500 x 3000 50 81,0 46 90 2,9 No.1724/P-CPR/2021

 

 
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
COOLFIRE- FR, BR Fire-rated frameless glass wall structures - EI30, EI60, EI90, EI120
 

 

FR variant Fire resistance Max. Glass
size in mm
Thickness in mm Light transmission
in %
Rw (dB) Weight
kg/m2
U-value
(W/m2K)
DoP
FR-EI30 EI30 1500 x 3000* 20 87,6 40 38 4,4 No.4325/P-CPR/2022
FR-EI60 EI60 1500 x 3000* 25 87,1 42 45 4,0 No.4130/P-CPR2021
FR-EI90 EI90 2000 x 3000* 35 85,5 44 52 3,3 No.4333/P-CPR2022
FR-EI120 EI120 1500 x 3000* 35 85,5 45 57 3,4 No.4114/P-CPR2022
FR-EI180 EI180 1500 x 3000* 55 85,3 45 83 NPD 65

 *Or 3000x1500 // **Affects the glass thickness

 

Covering of a fire-rated glass wall  built in plasterboard wall
Covering of a fire-rated glass wall built in plasterboard wall

 

 

  • Market6 Headquarters - EI60 Coolfire-Sapa 74 fireproof glazed door in the BR-EI60 fire-rated frameless glass wall
  • Graphisoft Park EI30 - Frameless fire-rated glass wall system Graphisoft Park EI30
  • GTC Pillar Office Building – Coolfire-BR EI120 Frameless fire-rated glass wall system
  • Vision Hotel - Fireproof glass door with frameless curved transom panel EI90
  • Graphisoft Park EI30 - Frameless fire-rated glass wall system Graphisoft Park EI30
  • Graphisoft Park EI30 - Frameless fire-rated glass wall system Graphisoft Park EI30
  • CCC Csillagvár Frameless fire-rated glass wall
  • Frameless fire-rated glass wall system
  • Frameless fire-rated glass wall system

See our frameless fire-rated FR, BR glass wall references

 

Coolfire Limited liability company

Coolfire Limited liability company
Headquarters: 9 Illatos street, Budapest 1098, Hungary
Company registration number: Cg.01-09-912574
Companies registration office: Fővárosi Törvényszék Cégbírósága
VAT registration number: 14628214-2-43.
Phone number: +36 20 387 5286
Email address: info@coolfire.hu
Legal Declaration

Follow us on Facebook

Follow us on Facebook