Fire-resistant sliding gates

Fireproof sliding gates


Fireproof sliding gates


Coolfire – NS Fireproof sliding gate EI120

One of the most cost-effective solutions for securing the openings at the boundary of the fire section against fire is a horizontally sliding, single and double leaf, even telescopically openable Fireproof sliding gate. It is only for protection against fire, it is not suitable for daily use, multiple opening and closing.

Benefits:

  • The passage between two adjacent rooms, which are bounded by a fire section, can be ensured by using a Fireproof sliding gate, with fire emergency closing
  • Can be mounted with personal entrance door 1250 * 2150mm, which can be glazed with 300 * 400mm glass panel and can be equipped with panic function
  • Optional: smoke detection unit, emergency switch
  • Available with single and double leaf design that slides to the side, or with single and double leaf design that telescopically slides in case of lack of space.

 


Techincal data, applicable sizes, space requirements

Coolfire-NS1
Single leaf sliding gate (EI120)
Maximum opening size 4000 x 4000mm
Side requirements  
-weight chamber is located on the opening side Opening width + 240 mm on the opening side
50mm on the closing side
-weight chamber is located on the closing side Opening width + 180 mm on the opening side
180mm on the closing side
Minimum bridging height 250 mm
200 mm in special cases
Coolfire-NS2
Double leaf sliding gate (EI120)
Maximum opening size 8400 x 4000mm
Side space requirements Half of the opening width+150mm on one side
Half of the opening width+175mm on the other side
Minimum bridging height 250 mm
200 mm in special cases
Coolfire-NS1-T
one-way telescopic sliding gate (EI120)
Maximum opening size 4200 x 4000mm
Side requirements needs (weight chamber is located on the opening side) Half of the opening width+150mm on the opening side
180mm on the closing side
Minimum bridging height 350 mm
Coolfire-NS2-T
Two-way telescopic sliding gate (EI120)
Maximum opening size 8400 x 4000mm
Side requirements needs, on both sides A quarter of the opening width +245 mm
Minimum bridging height 350 mm
   
Integrated in passageway door 1100 x 2100 mm
Looking glass panel 300 x 400 mm

 

Application:

Openings in the fire section partitioning wall of factories, plants, warehouses, underground garages, through which car and forklift traffic must be provided


Look:

The door leaf operates on a suspended guide rail and is kept open by a 24V magnet. In the event of a fire, the fire alarm system sends a signal and the magnet releases, the door leaf closes due to a counterweight system. It can be opened by hand, the magnet keeps it open again. In special cases, with a deviation permission, the sliding gate can be mounted in a sandwich-structured composite or plasterboard opening, using a steel support structure


Ral colours:

It comes with RA: 7035 by default, on request it can be ordered painted in a custom colour. RAL 7035, 1013, 5010, 7016, 9006, 9010, RAL 1001, 3003, 5009, 5012, 5015, 5024, 6005, 6011, 7001, 7031, 7032, 8019, 9001, 9005, 9016


Extras:

It can also be used in extra large sizes, advance consultation if required

 

  • Fireproof sliding gate
  • Fireproof sliding gate
  • Fireproof sliding gate
  • Fireproof sliding gate

See our Fireproof sliding gate references

 

 NS1 single leaf sliding gate – EI120

Vízszintes metszetStandard placement
(on walls behind the opening of opening, closing side)

Fordított elhelyezésReverse placement
(counterweight box on the opening side in case the closure is perpendicular to the wall)

 

NS2 double leaf sliding gate – EI120NS2 kétszárnyú tolókapu – EI120

Standard elhelyezésStandard placement
(there is enough space for the door leaf on the opening side)

Fordított elhelyezésReverse placement
(there is not enough space for the door leaf on the opening side)

 

EI120  - NS2 double leaf, one-way telescopic sliding gate – EI120EI120 - NS2 double leaf, one-way telescopic sliding gate – EI120

EI120 - NS2+2 four leaf, two-way   telescopic sliding gate – EI120EI120 - NS2+2 four leaf, two-way telescopic sliding gate – EI120

Passageway door integrated in a sliding gatePassageway door integrated in a sliding gate

Normal opening direction / Opposite opening directionNormal opening direction / Opposite opening direction

 

 

Coolfire Limited liability company

Coolfire Limited liability company
Headquarters: 9 Illatos street, Budapest 1098, Hungary
Company registration number: Cg.01-09-912574
Companies registration office: Fővárosi Törvényszék Cégbírósága
VAT registration number: 14628214-2-43.
Phone number: +36-20-283-9404
Email address: info@coolfire.hu

Follow us on Facebook

Follow us on Facebook